Volume 1, Issue 1 (April 2016)

Table of contents

Original research papers

Neutron and
Heavy Ion Radiations

THE SPECIAL TRANS FUNCTIONS THEORY FOR THE DEGREE OF NUCLEAR FUEL BURN-UP ESTIMATION

Slavica M. Perovich, Martin P. Calasan

Pages: 1-6

DOI: 10.21175/RadJ.2016.01.01

Received: 17 MAR 2015, Received revised: 11 MAY 2015, Accepted: 15 MAY 2015, Published Online: 28 APR 2016

The problem of finding an exact analytical closed form solution to the degree of the nuclear fuel burn-up simple transcendental equation is studied in some detail, by using the Special trans functions theory (STFT). Structure of the STFT solutions, derivations, numerical results and graphical simulations confirm the validity and base principle of the STFT
  1. V.V. Frolov, Ядерно-физические методы контроля делящихся веществ (Nuclear-Physical Methods of Fissile Materials Control), Moskow, Russia: Энергоатомиздат, 1989.
  2. S.M. Perovic and S. Jovanovic, “A Contribution to the Theory of the Slowing Down in the Carbide of Silicium,” Proc. in Int. Conf. Signal & Systems, vol. 2, Geneva, Switzerland, June 17-19, 1992, pp. 173-180.
  3. R. Gregg, A. Worrall, “Effect of Highly Enriched/ Highly Burnt UO2 Fuels on Fuel Cycle Costs, Radiotoxicity and Nuclear Design Parameters,” Nuclear Technology, Vol. 151, no. 2, pp.126-132, Aug., 2005.
  4. J. Secker et al., “Optimum Discharge Burn-up and Cycle Length for PWRs”, Nuclear Technology, vol. 151, no.2, pp. 109-111, Aug., 2005.
  5. “Experimental Investigation of Burn-up Credit for Safe Transport, Storage, and Disposal of Spent Nuclear Fuel,” NERI 2001 Annual Report, NERI 99-200, US Department of Energy, Washington DC, USA, DOE/NE-0122, pp. 211-212.
  6. S.M. Perovich, “Transcendental Method in the Theory of Neutron Slowing Down,” J Phys A: Math.Gen., vol. 25, no.10, pp. 2969-2689, 1992.
    DOI: 10.1088/0305-4470/25/10/024
  7. S.M. Perovich, “Reply to the Comment on the Transcendental Method,” J Phys A: Math.Gen., vol. 28, no. 14, pp. 4191-4200, 1995.
    DOI: 10.1088/0305-4470/28/14/035
  8. S.M. Perovich, D.V. Tosic, “Transcendental Method in the Nonlinear Circuits Theory,” Electron. Lett, vol. 32, no. 16, pp. 1433-1437, 1996.
    DOI: 10.1049/el:19961000
  9. S.M. Perovich, “Concerning the Analytical Solution of the Disperse Equation in the Linear Transport Theory,” Transport Theory and Statistical Physics, vol. 6, iss. 6, pp. 705-725, 1997.
    DOI: 10.1080/00411459708229331
  10. S.M. Perovich et al., “Some Comments Concerning the Discrete Eigen value,” Nucl. Sci. Eng., vol. 131, no. 3, p. 439, 1999.
  11. S.M. Perovich, S.I. Bauk, “The Analytical Analysis of Hopfield Neuron Parameters by the Application of the Special Trans Function Theory,” in Adaptive and Natural Computing Algorithms, B. Ribeiro, R.F. Al- brecht, A. Dobnikar, D.W. Pearson, N.C. Steele, Eds., New York (NY), USA: Springer, pp. 29–32, 2005.
    DOI: 10.1007/3-211-27389-1_9
  12. S.M. Perovich et al. “On the Analytical Solution of Some Families of Transcendental Equation,” Appl. Math. Lett., vol. 20, iss. 5, p. 493, 2007.
    DOI: 10.1016/j.aml.2006.06.008
  13. N.S. Singh, et al, “Determination of the Solar Cell Junction Ideality Factor Using Special Trans Function Theory (STFT),” Sol. Energy Mater Sol. Cells, vol. 93, iss. 8, pp. 1423-1426, 2009.
    DOI: 10.1016/j.solmat.2009.03.013
  14. S.M. Perovich, S.I. Bauk, “Determination of the Pluto- nium Temperature Using the Special Trans Functions Theory,” Nucl. Tech. & Rad. Protect., vol. 25, iss. 3, pp. 164-170, 2010.
    DOI: 10.2298/NTRP1003164P
  15. S.M. Perovich, S.I. Bauk, “An Inverse Problem of Tempe- rature Estimation for the Combination of the Linear and Non-Linear Resistances,” AIP Advances in Physics, vol. 022110, pp. 1-14, 2011.
    DOI: 10.1063/1.3589909
  16. S.M. Perovich, “The Special Trans Functions Theory,” Research Monograph, Podgorica, Monte Negro: Univ. of Montenegro, 2004.
  17. S.M. Perovich et al., “On the Exact Analytical Solution of Certain Lambert Transcendental Equation,” Math. Probl. Eng., vol. 2011, pp. 1-21, 2011.
    DOI: 10.1155/2011/685485
  18. N.S. Singh et al., “A New Method to Determine the Optimum Load of a Real Solar Cell Using Special Trans Function Theory (STFT),” Int. Jour. Renew. En. Res., vol. 3, no. 2, pp. 378-382, 2013.
  19. S.M. Perovich, M. Orlandic, M. Calasan, “Concerning Exact Analytical STFT Solution to Some Families of Inverse Problems in Engineering Material Theory,” Appl. Math. Modell., vol. 37, iss. 7, pp. 5474-5497, Apr., 2013.
    DOI: 10.1016/j.apm.2012.10.052
  20. S. Marguet, La physique des reacteurs nucleaires (The Physics of Nuclear Reactors), 1st and 2nd ed., Paris, France: Lavoisier, p. 471, 2011, and p. 512, 2013.
  21. S.M. Perovich, M. Calasan, R. Toskovic, “On the Exact Analytical Solution of Some Families of Equilibrium Critical Thickness Transcendental Equations,” AIP Advances 4, vol. 117124, 2014.
    DOI: 10.1063/1.4902161
  22. S.M. Perovich et al., “Concerning a Novel Mathematical Approach to the Solar Cell Junction Ideality Factor Estimation,” Appl. Math. Modell., vol. 39, iss. 12, pp. 3248-3264, June 2015.
    DOI: 10.1016/j.apm.2014.11.026
  23. S.M. Perovich et al., “Concerning Current STFT Estima- tions to the RC Diode Circuit,” 3rd Mediter. Conf. Embed. Comp., Budva, Montenegro, 15-19, June, 2014, pp. 193-197.
    DOI: 10.1109/MECO.2014.6862692
Radiation Detectors

BURIED GRAPHITE PILLARS IN SINGLE CRYSTAL CVD DIAMOND: SENSITIVITY TO ELECTRONS

G. Conte, P. Allegrini, M. Pacilli, S. Salvatori, D.M. Trucchi, T. Kononenko, A. Bolshakov, V. Ralchenko, V. Konov

Pages: 7-13

DOI: 10.21175/RadJ.2016.01.02

Received: 24 FEB 2015, Received revised: 15 APR 2015, Accepted: 19 APR 2015, Published Online: 28 APR 2016

The charge collection performance of a diamond-graphite detector is reported. Buried graphite pillars with high aspect ratio were formed inside a single crystal synthetic diamond slab by using a femtosecond IR laser with 200 kHz of repetition rate. Grouped in two series and connected by graphite strips on the surface, eight independent 3D electrodes were used to collect the charge carriers generated by energy deposited in the detector. Collimated 90Sr,Y -particles were used to test the charge collection in coincidence and self-triggering mode among pillars rows using different irradiation geometries. The charge collected by one pillar row saturates at 1.40±0.02 fC at ±0.67V/m with electrons impinging orthogonally the rows demonstrating a high charge carrier collection efficiency.
  1. M. Girolami, P. Allegrini, G. Conte, S. Salvatori, D.M. Trucchi and V. Ralchenko, “Diamond Detectors for UV and X-Ray Source Imaging,” IEEE-EDL, vol. 33, no.2, pp. 224-226, Feb. 2012.
    DOI: 10.1109/LED.2011.2176907
  2. W. Adams et al. (The RD42 Collaboration), “Radiation Hard Diamond Sensors for Future Tracking Applications,” Nucl. Inst. Meth. Phys. Res., vol. A565, no.1, pp. 278–283, June 2006.
  3. M. Pomorski et al., “Development of Single-Crystal CVD-Diamond Detectors for Spectroscopy and Timing,” Phys. Stat. Sol. (A), vol. 203, no. 12, pp. 3152–3160, Dec. 2006.
    DOI: 010.1002/pssa.200671127
  4. M. Pacilli et al., “Beta Particles Sensitivity of an All-Carbon Detector,” Nucl. Inst. Meth. Phys. Res., vol. A738, pp. 119-125, Feb. 2014.
    DOI: 10.1016/j.nima.2013.12.022
  5. A. Oh, B. Caylar, M. Pomorski and T. Wengler, “A Novel Detector with Graphitic Electrodes in CVD Diamond,” Diamond Relat. Mater., vol. 38, pp. 9–13, 2013.
    DOI: 10.1016/j.diamond.2013.06.003
  6. T. Kononenko et al., “All-Carbon Detector with Buried Graphite Pillars in CVD Diamond,” Appl. Phys., vol. A114, pp. 297-300, Nov, 2013.
    DOI: 10.1007/s00339-013-8091-7
  7. S. Lagomarsino et al., “Three-Dimensional Diamond Detectors: Charge Collection Efficiency of Graphitic Electrodes,” Appl. Phys. Lett., vol. 103, pp. 233507-10, Feb. 2013.
    DOI: 10.1063/1.4839555
  8. T.V. Kononenko,V.I. Konov,S.M. Pimenov,N.M. Ros-sukanyi, A.I. Rukovishnikov and V. Romano, “Three-Dimensional Laser Writing in Diamond Bulk,” Diamond Relat. Mater., vol. 20, pp. 264-268, Jan. 2011.
    DOI: 10.1016/j.diamond.2010.12.013
  9. V.P. Popov, L.N. Safronova, O.V. Naumova, D.V. Ni- kolaev, I.N. Kupriyanov and Yu.N. Palyanov, “Con-ductive Layers in Diamond Formed by Hydrogen Ion Implantation and Annealing”, Nucl. Inst. Meth. Phys. Res., vol. B282, pp. 100–107, Jan. 2012.
    DOI: 10.1016/j.nimb.2011.08.050
  10. F. Picollo et al., “Fabrication and Electrical Characterization of Three-Dimensional Graphitic Microchannels in Single Crystal Diamond,” New Jour. Phys., vol. 14, pp. 053011-20, May 2012.
    DOI: 10.1088/1367-2630/14/5/053011
  11. B. Sun, P.S. Salter and M.J. Booth, “High Conductivity Micro-Wires in Diamond Following Arbitrary Paths,” Appl. Phys. Lett., vol.105, pp. 231105 (1-4), Dec. 2014.
    DOI: 10.1063/1.4902998
  12. S. Zhao, “Characterization of the Electrical Properties of Polycrystalline Diamond Films,” Ph.D. dissertation, Dept. Phys., Ohio State Univ., Columbus, USA, 1994.
  13. B. Caylar, M. Pomorski and P. Bergonzo, “Laser-Processed Three Dimensional Graphitic Electrodes for Diamond Radiation Detectors”, Appl. Phys. Lett., vol.103, pp.043504 (1-3), July 2013.
    DOI: 10.1063/1.4816328
  14. S. Lagomarsino et al., “Electrical and Raman-Imaging Characterization of Laser-Made Electrodes for 3D Diamond Detectors”, Diamond Relat. Mat., vol. 43, pp.23-28, Mar. 2014.
    DOI: 10.1016/j.diamond.2014.01.002
  15. T.V. Kononenko, A.A. Khomich and V.I. Konov, “Peculiarities of Laser-Induced Material Transforma-tion Inside Diamond Bulk,” Diamond Relat. Mater., vol. 37, pp. 50–54, Aug. 2013.
    DOI: 10.1016/j.diamond.2013.04.010
Radiation Effects

THE EFFECT OF Xe ION AND NEUTRON IRRADIATION ON THE PROPERTIES OF SiC AND SiC(N) FILMS PREPARED BY PECVD TECHNOLOGY

Jozef Huran, Ladislav Hrubčín, Pavel Boháček, Sergey B. Borzakov, Vladimir A. Skuratov, Alexander P. Kobzev, Angela Kleinová, Vlasta Sasinková

Pages: 14-19

DOI: 10.21175/RadJ.2016.01.03

Received: 14 MAR 2015, Received revised: 20 APR 2015, Accepted: 24 APR 2015, Published Online: 28 APR 2016

Silicon carbide (SiC) and nitrogen-doped silicon carbide (SiC(N)) films were deposited on p-type Si(100) substrates at various deposition conditions by means of plasma enhanced chemical vapor deposition (PECVD) technology using silane (SiH4) methane (CH4) and ammonium (NH3) gas precursors. The concentration of elements in films was determined by RBS and ERD analytical method simultaneously. Chemical compositions were analyzed by FT-IR and Raman spectroscopy. The current-voltage (I-V) characteristics of structures before and after Xe ion and neutron irradiation were measured.
  1. D. Pysch et al., “Potentials and Development of Amorphous Silicon Carbide Heterojunction Solar Cells,” Proc. 34th IEEE Photov. Spec. Conf., Philadelphia (PA), USA, 2009, pp. 794-799.
    DOI: 10.1109/PVSC.2009.5411165
  2. S. Janz, S. Reber and W. Glunz, “Amorphous SiC: Applications for Silicon Solar Cells,” Proc. 21st EUPVSEC, Dresden, Germany, 2006, pp. 660-663.
  3. T.A. Pomorski, B.C. Bittel, C.J. Cochrane, P.M. Lenahan, J. Bielefeld and S.W. King, “Defects and Electronic Transport in Hydrogenated Amorphous SiC Films of Interest for Low Dielectric Constant Back End of the Line Dielectric Systems,” J. Appl. Phys., vol. 114, p. 074501, 2013.
    DOI: 10.1063/1.4818480
  4. S.W. King et al., “Influence of Network Bond Percolation on the Thermal, Mechanical, Electrical and Optical Properties of High and Low-k a-SiC: H Thin Films,” J. Non-Crystal. Solids, vol. 379, pp. 67–79, Nov. 2013.
    DOI: 10.1016/j.jnoncrysol.2013.07.028
  5. W. Daves, A. Krauss, N. Behnel, V. Häublein, A. Bauer and L. Frey, “Amorphous Silicon Carbide Thin Films (a-SiC:H) Deposited by Plasma-Enhanced Chemical Vapor Deposition as Protective Coatings for Harsh Environ-ment Applications,” Thin Solid Films, vol. 519, pp. 5892-5898, Jul. 2011.
    DOI: 10.1016/j.tsf.2011.02.089
  6. A.M. Wrobel, A. Walkiewicz-Pietrzykowska and P. Uznanski, “Remote Hydrogen Microwave Plasma Chemical Vapor Deposition from Methylsilane Precur-sors. 1. Growth Mechanism and Chemical Structure of Deposited a-SiC:H Films,” Thin Solid Films, vol. 564, pp. 222-231, Aug. 2014.
    DOI: 10.1016/j.tsf.2014.04.087
  7. 刘贵昂,谢二庆,王天民, “a-SiC: H薄膜的中子辐照研究,” Qiangjiguang Yu Lizishu, 第 15卷 第 3期 2003年 3月. (G.A. Liu, E.Q. Xie and T.M. Wang, “Irradiation Effect of Neutrons on a-SiC:H Films,” High Pow. Las. Part. Beams, vol. 15, no.3, pp. 271-274, Mar. 2003.)
  8. A. Gali, P. Deák, P. Ordejón, N. T. Son, E. Janzén and W. J. Choyke, “Aggregation of Carbon Interstitials in Silicon Carbide: A Theoretical Study,” Phys. Rev., vol. B 68, pp. 125201 (11), Sep. 2003.
    DOI: 10.1103/PhysRevB.68.125201
  9. A.P. Kobzev, J. Huran, D. Maczka and M. Turek, “Investi-gation of Light Element Contents in Subsurface Layers of Silicon,” Vacuum, vol. 83, supl.1, pp. S124-S126, May, 2009.
    DOI: 10.1016/j.vacuum.2009.01.042
  10. S.F. Yoon and J. Ahn, “Electron Cyclotron Resonance Deposition of Wide Bandgap a-SiC:HFilms Using Acetylene Under High Hydrogen Dilution,” J. Mater. Sci. Technol., vol. 13, no. 3, pp. 189-193, 1997.
  11. M.A. Fraga, M. Massi, I.C. Oliviera, H.S. Maciel, S.G.S. Filho and R.D. Mansano, “Nitrogen Doping of SiC Thin Films Deposited by RF Magnetron Sputtering,” J. Mater. Sci., vol. 19, no. 8, pp. 835-840, Sep. 2008.
    DOI: 10.1007/s10854-007-9487-y
  12. M. Künle, T. Kaltenbach, P. Lӧper, A. Hartel, S. Janz, O. Eibl and K-G. Nickel, “Si-rich a-SiC: H Thin Films: Structural and Optical Transformations during Thermal Annealing,” Thin Solid Films, vol. 519, no.1, pp. 151-157, Oct. 2010.
    DOI: 10.1016/j.tsf.2010.07.085
  13. J.K. Seo, Y-H. Joung, Y. Park and W.S. Choi, “Substrate Temperature Effect on the SiC Passivation Layer Synthesized by an RF Magnetron Sputtering Method,” Thin Solid Films, vol. 519, pp. 6654–6657, Aug. 2011.
    DOI: 10.1016/j.tsf.2011.04.052
  14. T. Chen, Y. Huang. D. Yang, R. Carius and F. Finger, “Development of Microcrystalline Silicon Carbide Window Layers by Hot-Wire CVD and their Applications in Microcrystalline Silicon Thin Film Solar Cells,” Thin Solid Films, vol. 519, no. 14, pp. 4523–4526, May 2011.
    DOI: 10.1016/j.tsf.2011.01.299
  15. В.И. Авраменко, Ю.В. Конобеев и А.М. Строкова “Нейтронные сечения для расчёта повреждающей дозы в реакторных материалах,” Атомная енергия, т. 56. но. 3, с. 139-141, 1984. (V.I. Avramenko, Yu.V. Konobeev and A.M. Strokova, “Neutron Cross-sections for Calculation of the Reactor Materials Damage Dose,” (Atomic Energy), vol. 56, no. 3, pp. 139-141, 1984.
  16. National Nuclear Data Center, Upton (NY), USA. Retrieved from: http://www.nndc.bnl.gov/
  17. M. Vetter et al., “Electronic Properties of Intrinsic and Doped Amorphous Silicon Carbide Films,” Thin Solid Films, vol. 511-512, pp. 290-294, Jul. 2006.
    DOI: 10.1016/j.tsf.2005.11.108
Radiation Effects

THE INFLUENCE OF DEVICE GEOMETRY ON THE PARTIALLY DEPLETED SOI TRANSISTOR TID HARDNESS

Ivan Shvetsov-Shilovskiy, Anatoly Smolin, Pavel Nekrasov, Anastasia Ulanova, Alexander Nikiforov

Pages: 20-25

DOI: 10.21175/RadJ.2016.01.04

Received: 15 MAR 2015, Received revised: 15 MAY 2015, Accepted: 18 MAY 2015, Published Online: 28 APR 2016

The research is focused on the differences in radiation behavior for transistors of different geometry, body tie contact types, device layer thickness and biasing.
  1. A.V. Sogoyan, A.I. Chumakov and A.Y. Nikiforov, “Method for Predicting CMOS Parameter Degradation Due to Ionizing Radiation with Regard to Operating Time and Conditions,” Russ. Microel., vol. 28, no. 4, pp. 224-235, 1999.
  2. M. Li et al., “Including Radiation Effects and Dependencies on Process-Related Variability in Advanced Foundry SPICE Models Using a New Physical Model and Parameter Extraction Approach,” IEEE Trans. Nucl. Sci., vol. 58, no. 6, pp. 2876-2882, Dec. 2011.
    DOI: 10.1109/TNS.2011.2171503
  3. K.O. Petrosyants, L.M. Sambursky, I.A. Kharitonov and A.P. Yatmanov, “SOI/SOS MOSFET Compact Macromodel Taking into Account Radiation Effects,” Russ. Microel., vol. 40, no 7, pp. 457‑462, Dec. 2011.
    DOI: 10.1134/S106373971107016X
  4. K.O. Petrosyants, I.A. Kharitonov, L.M. Sambursky, V.N. Bogatyrev, Z.M. Povarnitcyna and E.S. Drozdenko, “Simulation of Total Dose Influence on Analog-Digital SOI/SOS CMOS Circuits with EKV-RAD Macromodel,” inIEEE East-West Des.& Test Symp., Rostov-on-Don, Russia, Sep.27‑30, 2013,pp.1-6.
    DOI: 10.1109/EWDTS.2013.6673145
  5. A.V. Kirgizova, P.K. Skorobogatov, A.Y. Nikiforov, L.N. Kessarinskii, G.G. Davydov and A.G. Petrov, “Simulating the Response of SOS CMOS Building Blocks to Pulsed Ionizing Irradiation,” Russ. Microel., vol. 37, no. 1, pp. 25-40, Jan. 2008.
    DOI: 10.1134/S1063739708010046
  6. 6. O.A. Kalashnikov and A.Y. Nikiforov, “TID Behavior of Complex Multifunctional VLSI Devices,” in Proc. 29th Int. Conf. on Microelectronics, Belgrade, Serbia, May 2014, pp. 455-458.
    DOI: 10.1109/MIEL.2014.6842189
  7. 7. D.Boychenko, O. Kalashnikov, A.Yu. Nikiforov, A. Ulanova, D. Bobrovsky and P. Nekrasov, “Total Ionizing Dose Effects and Radiation Testing of Complex Multifunctional VLSI Devices,” Facta Univ./Ser: Electr. Ener., vol. 28, no. 1, pp. 153–164, Mar. 2015.
    DOI: 10.2298/FUEE1501153B
  8. 8. O.A. Kalashnikov, “Statistical Variations of Integrated Circuits Radiation Hardness,” in Proc. 12th Eur. Conf. Rad. Eff. Comp. Sys., Sevilla, Spain, Sep. 19-23, 2011, pp. 661-664.
    DOI: 10.1109/RADECS.2011.6131443
  9. V.V. Belyakov et al., “Methods for the Prediction of Total-Dose Effects on Modern Integrated Semiconductor Devices in Space: A Review,” Russ. Microel., vol. 32, no. 1, pp. 25-39, Jan. 2003.
    DOI: 10.1023/A:1021809802818
  10. A.V. Sogoyan, A.S. Artamonov, A.Y. Nikiforov and D.V. Boychenko. “Method for Integrated Circuits Total Ionizing Dose Hardness Testing Based on Combined Gamma- and Xray- Irradiation Facilities,” Facta Univ./Ser: Electr. Ener., vol. 27, no. 3, pp. 329-338, Sep. 2014.
    DOI: 10.2298/FUEE1403329S
  11. A.I. Chumakov, A.T. Nikiforov, V.A. Telets, V.F. Gerasimov, A.V. Yanenko and A.V. Sogoyan, “IC Space Radiation Effects Experimental Simulation and Estimation Methods,” Rad. Meas., vol. 30,no. 5, pp. 547-552, Oct. 2011.
    DOI: 10.1016/S1350-4487(99)00227-9
  12. B. Jianhui, B. Jinshun, L. Mengxin, and H. Zhengsheng “A Total Dose Radiation Model for Deep Submicron PDSOI NMOS,” J. Semicond., vol. 32, no. 1, pp. 014002 (1-3), Jan. 2011.
    DOI: 10.1088/1674 -4926/32/1/014002
  13. 13. L. Yanfeng et al., “Including the Effects of Process-Related Variability on Radiation Response in Advanced Foundry Process Design Kits,” IEEE Trans. Nucl. Sci., vol. 57, no. 6, pp. 3570-3574, Dec. 2010.
    DOI: 10.1109/TNS.2010.2086478
  14. 14. V. Rusanovschi, M. Rusanovschi and P. Stoicev, “Dependencies of SPICE Level 3 Parameters on Irradiation,” Merid. Inginer., vol. 4, pp. 19‑22, 2013.
  15. 15. Y. Wang et al., “Bias Dependence of Partially-
    Depleted SOI Transistor to Total Dose Irradiation, ”Int. Work. Junct. Techn., Shanghai, China, 2006, pp. 233-235.
    DOI: 10.1109/IWJT.2006.220899
  16. 16. P.K. Skorobogatov and A.Yu. Nikiforov, “Simulation of Bulk Ionization Effects in SOI Devices,” Russ. Microel., vol. 27, no. 1, pp. 1-6, 1998.
  17. 17. A.Yu. Nikiforov et al., “Experimental Studies of the Adequacy of Laser Simulations of Dose Rate Effects in Integrated Circuits and Semiconductor Devices,” Russ. Microel., vol. 38, no. 1, pp. 2-16, Jan. 2009.
    DOI: 10.1134/S1063739709010028
  18. G.I. Zebrev et al., “Radiation response of Bipolar Transistors at Various Irradiation Temperatures and Electric Biases: Modeling and Experiment,” IEEE Trans. on Nucl. Sci., vol. 53, iss. 4, pp. 1981-1987, Aug. 2006.
    DOI: 10.1109/TNS.2006.877851
  19. J.R. Schwank, V.Ferlet-Cavrois, M.R. Shaneyfelt, P. Paillet and P.E. Dodd, "Radiation Effects in SOI Technologies," IEEE Trans. Nucl. Sci., vol. 50, no.3, pp. 522-538, June 2003.
    DOI: 10.1109/TNS.2003.812930
  20. V. Ferlet-Cavrois et al., "Worst-Case Bias during Total Dose Irradiation of SOI Transistors," IEEE Trans. Nucl. Sci., vol. 47, no. 6, pp. 2183-2188, Dec. 2000.
    DOI: 10.1109/23.903751
  21. A.S. Artamonov et al., “REIS-IE' X-Ray Tester: Dеscription, Qualification Technique and Results, Dosimetry Procedure,” in IEEE Rad. Eff. Data Work., Newport Beach (CA), USA, Jul.24, 1998,pp. 164-169.
    DOI: 10.1109/REDW.1998.731498
Radiation Effects

MODELING AND PSPICE SIMULATION OF RADIATION STRESS INFLUENCE ON THRESHOLD VOLTAGE SHIFTS IN P-CHANNEL POWER VDMOS TRANSISTORS

Miloš Marjanović, Danijel Danković, Vojkan Davidović, Aneta Prijić, Ninoslav Stojadinović, Zoran Prijić, Nebojša Janković

Pages: 26-30

DOI: 10.21175/RadJ.2016.01.05

Received: 20 FEB 2015, Received revised: 12 MAY 2015, Accepted: 14 MAY 2015, Published Online: 28 APR 2016

In this paper the results of modeling and simulation of radiation stress effects in p-channel power VDMOSFET transistor have been presented. Based on measured results, the threshold voltage shifts as a function of absorbed dose and gate voltage during radiation stress have been modeled and implemented in the PSPICE model of the IRF9520 transistor. The transfer characteristics of the transistor are simulated and compared to the experimental ones. Difference is in the range 0.16% to 23.35% which represents a good agreement.
  1. Y. Deng, T. Ytterdal, T. Fjeldly and M. Shut, “SPICE Modeling of Double Diffused Vertical Power MOSFETs Exposed to Gamma Radiation,” Semicond. Dev. Res. Symp., Washington DC, USA, 2003, pp. 138-139.
    DOI: 10.1109/ISDRS.2003.1272031
  2. T.R. Oldham and F.B. McLean, “Total Ionizing Dose Effects in MOS Oxides and Devices,” IEEE Trans. Nucl. Sci., vol. 50, no. 3, pp. 483-499, June 2003.
    DOI: 10.1109/TNS.2003.812927
  3. S. Djoric–Veljkovic, I. Manic, V. Davidovic, D. Dankovic, S. Golubovic and N. Stojadinovic, “The Comparison of Gamma-Irradiation and Electrical Stress Influences on Oxide and Interface Defects in Power VDMOSFETs,” Nucl. Techn. & Rad. Prot., vol. 28, no. 4, pp. 406-414, 2013.
    DOI: 10.2298/NTRP1304406D
  4. G.S. Ristic, “Influence of Ionizing Radiation and Hot Carrier Injection on Metal-Oxide-Semiconductor Transistors,” (topical review), J. Phys. D: Appl. Phys., vol. 41, no.2, p. 023001, 2008.
    DOI: 10.1088/0022-3727/41/2/023001
  5. I. Manic, Z. Pavlovic, Z. Prijic, V. Davidovic and N. Stojadinovic, “Analytical Modelling of Electrical Characteristics in γ-Irradiated Power VDMOS Transistors,” Microel. J., vol. 32, no. 5, pp. 485-490, May 2001.
    DOI: 10.1016/S0026-2692(01)00019-2
  6. M.S. Andjelkovic, “A Review of Dosimetric Properties of RADFETs,” IEEESTEC – 7th Stud. Proj. Conf., Nis, Ser-bia, 2014, pp. 57-64.
  7. A. Ilic, Z. Prijic, A. Prijic, V. Davidovic, D. Dankovic and N. Stojadinovic, “Mobilna eksperimentalna postavka za odredjivanje napona praga VDMOS tranzistora snage (Mobile Experimental Setting for Determination of Threshold Voltage of VDMOS Power Transistors),” Zbornik Konferencije za ETRAN, Vrnjacka Banja, Serbia, June 2-5, 2014, vol.58, pp. MO1.2.1-4.
  8. IRF9520, Spice netlist. Retrieved from: www.vishay.com/docs/90308/sihf9520.lib
  9. “IRF9520,” Datasheet, Fairchild Semicond. Corp., Rev. B, 2002. Retrieved from: http://www.uib.es/depart/dfs/GTE/education/industrial/tec_analogiques/IRF9520.pdf.
  10. A. Ortiz-Conde, F.J. Garcia Sanchez, J.J. Liou, A. Cerdeira, M. Estrada and Y. Yue, “A Review of Recent MOSFET Threshold Voltage Extraction Methods,” Microelec. Reliab., vol. 42, no. 4-5, pp. 583-596, Apr.-May 2002.
    DOI: 10.1016/S0026-2714(02)00027-6
  11. A. Holmes-Siedle and L. Adams, “RADFET: A Review of the Use of Metal-Oxide-Silicon Devices as Integrating Dosimeters,” Int. J. Rad. App. Inst. Pt. C. Rad. Phys. Chem., vol. 28, no. 2, pp. 235-244, 1986.
    DOI: 10.1016/1359-0197(86)90134-7
  12. A. Jaksic, Y. Kimoto, V. Ogourtsov, V. Polischuk, A. Mohammadzadeh and A. Mathewson, “The Effect of Different Biasing Configurations on RADFET Response Measured by an Automated Read-Out System,” Proc. 7th Eur. Conf. Rad. Eff. Compon Sys., Noordwijk, Netherlands, Sept. 15-19, 2003, pp. 489-492.
Radiation
Measurements

BACKGROUND IN A TEST OF DETECTING “COOPERATIVE” PARAPOSITRONIUM ANNIHILATION BY THE 32-CRYSTAL SPECTROMETER ARGUS

Nevenka M. Antović, Sergey K. Andrukhovich, Alexandr V. Berestov

Pages: 31-35

DOI: 10.21175/RadJ.2016.01.06

Received: 14 FEB 2015, Received revised: 11 MAR 2015, Accepted: 15 MAR 2015, Published Online: 28 APR 2016

Parapositronium – a singlet positronium ground state, has the total angular momentum of electron and positron forming the atom Js = 0, magnetic quantum moment m = 0, and its annihilation spectrum is dominantly created by the 511 keV discrete photons. A process of cooperative emission of annihilation photons (cooperative annihilation) by a system of positronium atoms, i.e., annihilation superradiance, had been considered by other researchers, and the theory of annihilation superradiance in a system of parapositronium atoms for two-photon annihilation was constructed (two interacting parapositronium atoms; emission of the 1022 keV photons flying apart at an angle of 180°). The 32-crystal spectrometer ARGUS, with 16 detector pairs at an angle of 180° capable of registering double gamma coincidences, with lead collimators (80 mm in diameter) mounted on each detector – was used to test the phenomenon. Parapositronium annihilation spectra were acquired using 22Na (A = 4×105 Bq) as a positron source, and SiO2 (as „positronium forming“ medium; probability: 32 %), as well as Al (as „positronium not forming“ target) used as a blank – for estimation of the background events. In the case when after emission of two starting positrons from 22Na (i.e., the 1275 keV nuclear photons) coincident registration (respecting the spectrometer time resolution) of four annihilation photons should be considered as a six-fold coincidence event, experimentally obtained counting rates were – 0.25 s-1 (SiO2) and 0.23 s-1 (Al), while theoretically predicted – 0.34 s-1. The main background process competitive to a registration of the parapositronium cooperative annihilation is four-fold coincidence event (the two 180° detectors register 1275 keV photons, and two – summing of the 511 keV annihilation photons), with experimental counting rates – 0.026 s-1 (SiO2) and 0.023 s-1 (Al), as theoretically predicted – 0.023 s-1. On the other hand, cooperative annihilation should be a four-fold coincidence event (the two 180° detectors register 1275 keV photons, and two – 1022 keV photons), which has not been registered by the ARGUS spectrometer (theoretically predicted counting rate – 1.7×10-5 s-1). The analyses showed that probability of detecting the parapositronium cooperative annihilation will increase significantly with increasing positron source activity, but also with decreasing diameter of lead collimators.

  1. В.И. Гольданский, Физическая химия позитрона и позитрония, Москва, Россия: Нука, 1968. (V.I. Goldanskii, Physical Chemistry of Positron and Positronium, Moscow, Russia: Nauka, 1968.)
  2. M. Chiba, R. Hamatsu, T. Hirose, T. Matsumoto and J. Yang, “Measurement of Electron-Positron Annihilation at Rest into Four and Five Photons,” Nukleonika, vol. 42, no.1, pp. 61-68, Jan. 1997.
  3. S.K. Andrukhovich et al., “Investigation of Orthoposi-tronium 3g-Decay Using a Multidetector Spectrometer,” Nucl. Instrum. Meth. Phys. Res. Sec. B: Beam Int. Mat. Atoms, vol. 207, no. 2, pp. 219-226, June 2003.
    DOI: 10.1016/S0168-583X(03)00458-0
  4. B.K. Arbic, S. Hatamian, M. Skalsey, J. van House, W. Zheng, “Angular-Correlation Test of CPT in Polarized Positronium,” Phys. Rev., vol. 37, no. 9, pp. 3189-3194, 1988.
  5. S.K. Andrukhovich, N. Antovich, A.V. Berestov and O.N. Metelitsa, “Test CPT in the Decay of Polarized Positroni-um Using Multidetector spectrometer,” Mater. Sci. For., vol. 363-365, pp. 591-593, Apr. 2001.
    DOI: 10.4028/www.scientific.net/MSF.363-365.591
  6. P.A. Vetter and S.J. Freedman, “Search for CPT-Odd Decays of Positronium,” Phys. Rev. Lett., vol. 91, no. 26-31, p. 263401, Dec. 2003.
    DOI: 10.1103/PhysRevLett.91.263401
  7. Р.А. Власов, О.Н. Гадомский, В.В. Самарцев,
    “Аннигиляционное сверхизлучение в системе атомов позитрония и позитронная поляризация среды,” Теоретическая и математическая физ., т. 79, №. 3, с. 423-436, 1989. (R.A. Vlasov, O.N. Gadomskii and V.V. Samartsev, “Annihilation Superradiance in a System of Positronium Atoms and Positron Polarization of the Medium,” Theor. Math. Phys., vol. 79, no. 3, pp. 423–436, 1989.)
  8. O.N. Gadomskii, “The Positronium Atom in the Field of an Optical Laser: Radiation-Induced Energy Shifts and Annihilation Decay Kinetics,” J. Exp. Theor. Phys., vol. 83, no. 4, pp. 676-684, Sep. 1996.
  9. O.N. Gadomskii and T.T. Idiattulov, “Long-Lived Positro-nium Atom in the Field of an Optical Laser,” Quant. Electron., vol. 28, no. 6, pp. 469-473, 1998.
    DOI: 10.1070/QE1998v028n06ABEH001251
  10. L. B. Madsen and P. Lambropoulos, “Scaling of Hydroge-nic Atoms and Ions Interacting with Laser Fields: Posi-tronium in a Laser Field,” Phys. Rev. A, vol. 59, no. 6, pp. 4574-4579, June 1999.
    DOI: 10.1103/PhysRevA.59.4574
  11. L.B. Madsen, “Positronium in Laser Fields,” Nucl. Instr. Meth. B: Beam Inter. Mat. Atoms, vol. 221, no.1, pp. 174-181, July 2004.
    DOI: 10.1016/j.nimb.2004.03.051
  12. N. Antovic, “Investigation of Rare Positronium Decays on Multidetector Gamma-Coincidence Spectrometers,” PhD thesis, Faculty of Physics, University of Belgrade, Serbia, 2000. (in Serbian).
  13. С.К. Андрухович, А.В. Берестов, Ф.Е. Зязюля, Б.А. Марцынкевич, Е.А. Рудак, А.М. Хильманович, “Авто-матизированна регистрирующа гамма-установка совпадений (АРГУС), препринты в ИФ АН БССР, №. 408-409, 1986. ИФ АН БСС (S.K. Andrukhovich, A. V. Berestov, F.E. Zyazyulya, B.A. Marcinkevich, E.A. Rudak and A.M. Hil’manovich, [Automated Device for Registration of Gamma-Coincidences (ARGUS)],” Preprint in IF AN BSS, no. 408-409, 1986.)
  14. N.M. Antovic, S.K. Andrukhovich and A.V. Berestov, “A Contribution of the Compton Scattered Radiation from Mn-54 to Double Gamma Coincidences Spectra at the 32-Detector System,” in Proc. RAD 2014, Nis, Serbia, pp. 127-130.
  15. S.K. Andrukhovich, N.M. Antovich and A.V. Berestov, “Effect of Cascade Gamma-Radiation Summation Processes on the Precision of Calculating the Probability of Three-Photon Annihilation of Positronium,” Phys. Sol. State, vol. 42, но. 9, pp. 1648-1651, Sep. 2000.
    DOI: 10.1134/1.1309445
Radiation
Measurements

RESULTS FROM RADIONUCLIDE INTERLABORATORY COMPARISON OF SEDIMENT AND FISH

Gordana Pantelić, Péter Vancsura, Jelena Krneta Nikolić, Marija Janković, Nataša Sarap, Dragana Todorović, Milica Rajačić

Pages: 36-39

DOI: 10.21175/RadJ.2016.01.07

Received: 28 MAR 2015, Received revised: 22 MAY 2015, Accepted: 24 MAY 2015, Published Online: 28 APR 2016

The results of an intercomparison exercise, designed for the determination of anthropogenic and natural radionuclides in sediment and fish samples from the Danube River, are reported. The methods of gross beta and gamma spectrometry measurements were compared. Considering the uncertainties of measurements, a good agreement between the results obtained by two laboratories has been ascertained.
  1. G. Pantelic et al., “Radioactivity control of the Danube at Yugoslav-Hungarian border area,” Environmental Recovery of Yugoslavia, Vinca Institute, Belgrade, Serbia: 2002, pp. 193-201.
  2. “Method for Determining Gamma Emitters,” Technical Reports Series: Measurements of Radionuclides in Food and Environment, no. 295, Vienna, Austria: IAEA, 1989, Annex I, pp. 47-69
  3. J.D. Krneta Nikolic, D.J. Todorovic, M.M. Jankovic, G.K. Pantelic and M.M. Rajacic, “Quality Assurance and Quality Control in Environmental Radioactivity Monitoring,” Q. A. Safety Crops & Foods, vol. 6, no. 4,pp. 403-409, 2014.
    DOI: 10.3920/QAS2012.0.236
  4. “IAEA Analytical Quality in Nuclear Applications Series: Worldwide Open Proficiency Test: Determination of Naturally Occurring Radionuclides in Phosphogypsum and Water,” IAEA, Vienna, Austria, no. IAEA/AQ/18 (IAEA-CU-2008-03), 2010.
Radiation
Measurements

PERSONAL RADIATION DETECTOR γ-TRACER GT2-1 WITH A CdZnTe DETECTOR

S. Gushchin, V. Ivanov, A. Loutchanski, V. Ogorodniks

Pages: 40-45

DOI: 10.21175/RadJ.2016.01.08

Received: 13 MAR 2015, Received revised: 29 APR 2015, Accepted: 04 MAY 2015, Published Online: 28 APR 2016

The Personal Radiation Detector (PRD) γ-Tracer GT2-1 was developed with a focus on gamma-radiation searches and detection and offers a gamma-radiation source localization function, enhanced PRD features and the capability of isotope energy pattern analysis. The device complies with general requirements and includes all typical features of PRD-class devices as well as supplementary modes such as multi-channel scaling (MCS), a spectrometer, library-driven analysis and a data logger. The GT2-1 uses a detector module built around a 0.4 cm3 counting-grade planar CdZnTe detector. CdZnTe offers high-efficiency gamma-radiation detection for a small detector volume and energy discrimination down to 30 keV. The GT2-1 was designed with power consumption in mind; its typical lifetime after a full battery charge exceeds 600 hours in measurements mode. Energy compensation techniques are employed for the dose rate calculations. The typical accuracy of the device in the energy range of 30–1500 keV is better than 10% for factory-calibrated devices. The GT2-1 features a library-driven isotope identification function. Its underlying concept is the use of a library of pre-calibrated user-defined isotope patterns for comparison with the isotope under investigation. The identification algorithm is designed to evaluate the isotope energy pattern match. The execution of the algorithm yields the matching results between the tested isotope and the library in graphical form. The device’s search mode employs a proprietary Background Variation Tracking (BVT) algorithm. The implemented search and gamma-radiation source localization mechanisms facilitate the rapid (1–3 sec) detection of weak gamma-radiation sources with intensities that exceed the background level by a factor of 1.5–3. Analysis of the time intervals between adjacent pulses in the input sequence is used to determine numeric characteristics that are also displayed in a user-friendly graphical form. The dedicated GUI approach and sound capabilities are tailored to facilitate search activities and support the operator in gaining experience with the device. The dedicated search algorithm implementation allows the device to be used as a homeland security detector by services responsible for the control of the relocation of radioactive materials, such as those at airports, border control checkpoints, and tolls. Test results for the GT2-1 in search mode are presented.
  1. “Spectroscopic personal radiation detector identiFINDER R300,” FLIR Syst., Wilsonville (OR), USA, data sheets. Retrieved from: http://www.flir.com/ uploadedFiles/flirGS/Threat_Detection/Radiation_Detection/Products/IdenitiFINDER-300/DS_identiFINDER-R-300-en.pdf
  2. “Spectrometric Personal Radiation Detector GalaxRay,” Galaxray, data sheets, 2016. Retrieved from: http://www.galaxray.com/products.html#tabs-tab-title-2.
  3. V. Nagarkar, M. Squillante, G. Entine, I. Stern and D. Sharif, “CdTe Detectors in Nuclear Radiation Dosimetry,” Nucl. Instr. Meth. A, vol. 322, no. 3, pp. 623–627, Nov., 1992.
    DOI: 10.1016/0168-9002(92)91242-2
  4. 4В.С. Горев, В.А. Кожемякин, О.А. Матвеев, М.Д. Фирсов, А. Х. Хуcaинoв, Г.К. Шульгович, “Примене-ние детекторов на основе теллурида кадмия в дозиметрии гамма-излучения,” Приборы и техника Эксперимента, №. 1, с. 60–64, 1981. (V.S. Gorev, V.A. Kozhemyakin, O.A. Matveev, M.D. Firsov, A.H. Husainov, G.K. Shul’govich, “Cadmium Telluride Based Detectors for Gamma Radiation Dosimetry,” Instruments and Technique of Experiment, no. 1, pp. 60-64, 1981.)
  5. В.А. Мокрицкий, О.В. Маслов, О.В. Банзак, “Коррекция зависимости чувствительности CdZnTe-детектора от энергии гамма-излучения,” Збiрник наукових праць Вiйськового iнституту, Унiв. Тарас Шевченко, № 39, с. 81–84, 2013. (V.A. Mokrickii, O.V. Maslov, O.V. Banzak, “Correction of Gamma-Ray Energy Dependence Sensitivity of CDZnTe-Detector,” Monogr. Milit. Inst. Univ. Taras Shevchenko, no. 39, pp. 81-84, 2013.)
  6. Rybka A.V. et al., “Gamma-Radiation Dosimetry with Semiconductor CdTe and CdZnTe Detectors,” NIM A, vol. 531, no. 1-2, pp. 147–156, Sep. 2004.
    DOI: 10.1016/j.nima.2004.05.107
  7. R. Arlt et al., “Use of CdZnTe Detectors in Hand-Held and Portable Isotope Identifiers to Detect Illicit Trafficking of Nuclear Material and Radioactive Sources,” Nucl. Sci. Symp. Conf. Rec., IEEE 2000, vol.1, pp. 4/18–4/23.
    DOI: 10.1109/NSSMIC.2000.949040
  8. Retrieved from: http://www.maths.qmul.ac.uk/~bb/TS_Chapter4_34.pdf
Radiation Physics

LOW-ENERGY ELECTRON DAMAGE OF DPPC MOLECULES – A NEXAFS STUDY

R. Panajotović, S. Ptasinska, V. Lyamayev, and K. Prince

Pages: 46-50

DOI: 10.21175/RadJ.2016.01.09

Received: 26 MAR 2015, Received revised: 22 MAY 2015, Accepted: 24 MAY 2015, Published Online: 28 APR 2016

In cancer research the radiation dose delivered to different organs presents a critical parameter for destroying the cancer cells’ DNA, but the biochemical pathways that bring cells to death in many cases start at the cell membrane whose major part consists of lipid molecules. In our XPS and NEXAFS experiment, we exposed a monolayer lipid film supported on gold to a spatially and energetically well defined electron beam (20 eV), simulating the charged particle avalanche produced in the exposure of the biological tissue to a high-energy ionizing radiation (X- and g - rays, ions, etc). Oxygen and nitrogen 1s edge scans show a clear chemical degradation of the DPPC monolayer. The major damage has been inflicted to the polar head of the molecule and its links with the molecules’ alkane chains.
  1. T.A. Legace and N.D. Ridgway, “The Role of Phospholipids in the Biological Activity and the Structure of the Endoplasmatic Reticulum,” BBA – Molec. Cell Res., vol. 1833, no. 11, pp. 2499-2510, Nov. 2013.
    DOI: 10.1016/j.bbamcr.2013.05.018
  2. S. Mukherjee and A. Chattopadhyay, “Influence of Ester and Ether Linkage in Phospholipids on the Environment and Dynamics of the Membrane Interface: A Wavelength-Selective Fluorescence Approach,” Langmuir, vol. 21, no. 1, pp. 287-293, Nov. 2005.
    DOI: 10.1021/la048027+
  3. R.A. Bckmann and H. Grubmuller, “Multistep Binding of Divalent Cations to Phospholipid Bilayers: A Molecular Dynamics Study,” Angew. Chem. Int. Ed., vol. 3, no. 8, pp. 1021 –1024, Feb. 2004.
    DOI: 10.1002/anie.200352784
  4. E.T. Castellana and P.S. Cremer, “Solid Supported Lipid Bilayers: From Biophysical Studies to Sensor Design,” Surface Sci. Rep., vol. 61, no. 10, pp. 429–444, 2006. DOI: 10.1016/j.surfrep.2006.06.001
  5. A. Turchanin et al., “Molecular Self-Assembly, Chemical Lithography, and Biochemical Tweezers: A Path for the Fabrication of Functional Nanometer-Scale Protein Arrays,” Adv. Mat., vol. 20, no. 3, pp. 471-477, Feb. 2008.
    DOI: 10.1002/adma.200702189
  6. G. Ketteler et al., “In Situ Photoelectron Spectroscopy Study of Water Adsorption on Model Biomaterial Surfa-ces,” J. Phys. Condens. Matt., vol. 20, no. 18, pp. 184024, Apr. 2008.
    DOI: 10.1088/0953-8984/20/18/184024
  7. X. Liu et al., “Self-Assembly of Biomolecules at Surfaces Characterized by NEXAFS,” Can. J. Chem., vol. 85, no. 10, pp. 793-800, 2007.
    DOI: 10.1139/V07-079
  8. G. Hähner, “Near Edge X-Ray Absorption Fine Structure Spectroscopy as a Tool to Probe Electronic and Structural Properties of Thin Organic Films and Liquids,” Chem. Soc. Rev., vol. 35, no. 12, pp. 1244-1255, Dec. 2006.
    DOI: 10.1039/B509853J
  9. N.T. Samuel, C.Y. Lee, L.J. Gamble, D.A. Fischer and D.G. Castner, “NEXAFS Characterization of DNA Com-ponents and Molecular-Orientation of Surface-Bound DNA Oligomers,” J. Elect. Spec. Rel. Phen., vol. 152, no. 3, pp. 134-142, July 2006.
    DOI: 10.1016/j.elspec.2006.04.004
  10. V. Cherezov, K.M. Riedl and M. Caffrey, “Too Hot to Handle? Synchrotron X-Ray Damage of Lipid Membra-nes and Mesophases,” J. Synchr. Rad. , vol. 9, no. 6, pp. 333-341, Nov. 2002.
    DOI: 10.1107/S0909049502014528
  11. E. Novakova, G. Mitrea, C. Peth, J. Thieme, K. Mann, and T. Salditt, “Solid Supported Multicomponent Lipid Membranes Studied by X-Ray Spectromicroscopy,” Biointerph., vol. 3, no. 2, pp. FB44-FB54, June 2008.
    DOI: 10.1116/1.2976445
  12. LIPID Metabolites and Pathways Strategy “Lipid MAPS”, Data bases. Retrieved from: http://www.lipidmaps .org/resources/services.html.
  13. L. Sanche, “Low Energy Electron-Driven Damage in Biomolecules,” Eur. Phys. J. D, vol. 35, no. 2, pp. 367-390, Aug. 2005.
    DOI: 10.1140/epjd/e2005-00206-6
  14. R. Panajotovic, F. Martin, P. Cloutier, D. Hunting and L. Sanche, “Effective Cross Sections for Production of Single-Strand Breaks in Plasmid DNA by 0.1 to 4.7 eV Electrons,” Rad. Res., vol. 165, no. 4, pp. 452-459, Apr. 2006.
    DOI: 10.1667/RR3521.1
  15. R. Panajotovic, M. Michaud and L. Sanche, “Cross Sec-tions For Low-Energy Electron Scattering From Adenine in the Condensed Phase,” Phys. Chem. Chem. Phys., vol. 9, no. 1, pp. 138-148, Jan. 2007.
    DOI: 10.1039/B612700B
  16. E.B. Watkins, C.E. Miller, W.P. Liao, and T.L. Kuh, “Equilibrium or Quenched: Fundamental Differences between Lipid Monolayers, Supported Bilayers, and Membranes,” ACS Nano, vol. 8, no. 4, pp. 3181-3191, 2014.
    DOI: 10.1021/nn4052953
  17. R. Panajotovic, M. Schnietz, A. Turchanin, N. Mason, N. Mason, and A. Golzhauser, “Degradation of Phospholipid Molecules by Low-Energy Electrons,” Book of Abstr. Rad. Res. Soc. Conf., Sep. 25-29, 2010, Maui (Hi), USA, p.99.
  18. T. Hemraj-Benny et al., “Near-Edge X-ray Absorption Fine Structure Spectroscopy as a Tool for Investigating Nanomaterials,” Small, vol. 2, no. 1, 26-35, 2006.
    DOI: 10.1002/smll.200500256
  19. Community site for x-ray absorption fine-structure “XAFS”. Retrieved from: http://www.xafs.org.
  20. A.V. Naumkin, A. Kraut-Vass, S.W. Gaarenstroom and C. J. Powell, Eds., “NIST X-ray Photoelectron Spectroscopy Database,” Measurement Services Division of the NIST, USA, ref. db. 20, ver. 4.1, 2012. Retrieved from: http://srdata.nist.gov/xps/
  21. T.K. Sham, B.X. Yang, J. Kirz, J.S. Tse, “K-edge Near-Edge X-Ray-Absorption Fine Structure of Oxygen- and Carbon-Containing Molecules in the Gas Phase,” Phys. Rev. A, vol. 40, no.2, pp. 652-669, Aug. 1989.
    DOI: 10.1103/PhysRevA.40.652
  22. S. Bhattacharayya, M. Lubbe, P.R. Bressler, D.R. T. Zahn, F. Richter, “Structure of Nitrogenated Amorphous Carbon Films from NEXAFS”, Diamond and Rel. Mat., vol. 11, no. 1, pp. 8-15, Jan. 2002.
    DOI: 10.1016/S0925-9635(01)00525-8
  23. P. Leinweber et al., “Nitrogen K-Edge XANES – an Over-view of Reference Compounds Used to Identify ‘Un-known’ Organic Nitrogen in Environmental Samples,” J. Synch. Rad., vol. 14, no. 6, pp. 500-511, Nov. 2007.
    DOI: 10.1107/S0909049507042513
  24. S.S. Roy, P. Papakonstantinou, T.I.T. Okpalugo, and H. Murphy, “Temperature Dependent Evolution of The Local Electronic Structure of Atmospheric Plasma Treated Carbon Nanotubes: Near Edge X-Ray Absorption Fine Structure Study,” J. Appl. Phy., vol. 100, no. 5, pp. 053703, Sep. 2006.
    DOI: 10.1063/1.2260821
  25. 25. L. Pasquali et al., “UPS, XPS, and NEXAFS Study of Self-Assembly of Standing 1,4-Benzenedimethanethiol SAMs on Gold,” Langmuir, vol. 27, no. 8, pp. 4713–4720, Mar. 2011.
    DOI: 10.1021/la105063u
Radiation Protection

NON-TARGETED EFFECTS OF FACTORS FROM BLOOD SERUMS OF CHERNOBYL POPULATIONS

Pavel Marozik, Irma Mosse, Mikhail Marozik, Sergei Melnov, Colin Seymour, Carmel Mothersil

Pages: 51-56

DOI: 10.21175/RadJ.2016.01.10

Received: 06 MAR 2015, Received revised: 25 MAR 2015, Accepted: 29 MAR 2015, Published Online: 28 APR 2016

In the present work, the phenomenon of bystander effects (transfer of damaging factors from affected cells to intact cells) induced in vivo has been studied. A newly developed method allows evaluation of the effects of bystander factors from sera of different groups of populations on immortalized culture of human keratinocytes. This method has serious advantages as compared to that which was used earlier. The level of damaging bystander factors in blood of people irradiated by the Chernobyl accident was estimated. Affected population groups included liquidators of the Chernobyl accident and people living and working in areas of Gomel region contaminated by radionuclides. The data clearly shows that blood serum samples of irradiated populations contain some kind of factors, induced in vivo and able to cause cell damage when transferred to in vitro conditions. These factors are able to circulate in blood stream for more than 20 years.
  1. H. Nagasawa and J.B. Little, “Induction of Sister Chromatid Exchanges by Extremely Low Doses of Alpha-Particles,” Cancer Res., vol. 52, no. 22, pp.6394-6396, Nov. 1992.
  2. B.E. Lehnert and E.H. Goodwin, “A New Mechanism For DNA Alterations Induced by Alpha Particles Such as Those Emitted by Radon and Radon Progeny,” Envir. Health Persp., vol.105, suppl. 5, pp.1095–1101, Sep. 1997.
    DOI: 10.2307/3433515
  3. E.I. Azzam, S.M. de Toledo, T. Gooding and J.B. Little, “Intercellular Communication is Involved in the Bystander Regulation of Gene Expression in Human Cells Exposed to Very Low Fluencies of Alpha Particles,” Rad. Res., vol.150, no. 5, pp.497–504, Nov. 1998.
    DOI: 10.2307/3579865
  4. A. Bishayee, D.V. Rao and R.W. Howell, “Evidence for Pronounced Bystander Effects Caused by Nonuniform Distributions of Radioactivity Using a Novel Three-Dimensional Tissue Culture Model,” Rad. Res., vol.152, no.51, pp.88-97, July 1999.
    DOI: 10.2307/3580054
  5. C. Mothersill and C. Seymour, “Medium from Irradiated Human Epithelial Cells but not Human Fibroblasts Reduces the Clonogenic Survival of Unirradiated Cells,” Int. J. Rad. Biol., vol.71, no.4, pp.421-427, Apr. 1997.
    DOI: 10.1080/095530097144030
  6. K.M. Prise, O.V. Belyakov, M. Folkard and B.D. Micheal, “Studies on Bystander Effects in Human Fibroblasts Using a Charged Particle Microbeam,” Int. J. Rad. Biol., vol.74, no. 6, pp. 793-798, Dec. 1998.
    DOI: 10.1080/095530098141087
  7. I. Emerit et al., “Transferable Clastogenic Activity in Plasma from Persons Exposed as Salvage Personnel of the Chernobyl Reactor,” J. Canc. Res. Clin. Oncol., vol.120, no. 9, pp. 558-561, Sep. 1994.
    DOI: 10.1007/BF01221035
  8. K. Baverstock and O.V. Belyakov, “Some Important Questions Connected With Non-Targeted Effects”, Mutat. Res., vol.687, no. 1-2, pp. 84–88, May 2010.
    DOI: 10.1016/j.mrfmmm.2010.01.002
  9. I. Emerit, “Superoxide Generation by Clastogenic Factors,” in Free Radicals, Lipoproteins And Membrane Lipids, A. Crastes De Paulet, L. Douste-Blazy And R. Paoletti, Eds., New York (NY), USA: Plenum Press (Springer), 1991, sec. 1, pp.99-104.
    DOI: 10.1007/978-1-4684-7427-5_10
  10. I. Mosse, P. M. Marozik, C. Seymour and C. Mothersill, “The Effect of Melanin on the Bystander Effect in Human Keratinocytes,” Mutat. Res., vol.597, no. 1-2, pp. 133-137, May 2006.
    DOI: 10.1016/j.mrfmmm.2005.09.006
  11. I. Emerit et al., “Clastogenic Factors in the Plasma of Chernobyl Accident Recovery Workers: Anticlastogenic Effect of Ginkgo Biloba Extract,” Rad. Res., vol.144, no. 2, pp. 198-205, Nov. 1995.
    DOI: 10.2307/3579259
  12. I. Emerit et al., “Oxidative Stress-Related Clastogenic Factors in Plasma from Chernobyl Liquidators: Protective Effects of Antioxidant Plant Phenols, Vitamins and Oligoelements,” Mutat. Res., vol.377, no. 2, pp. 239-246, July 1997.
    DOI: 10.1016/S0027-5107(97)00080-8
Radiation Protection

ASSESSMENT OF OCCUPATIONAL DOSE IN FLUOROSCOPY PROCEDURES WHEN INDIVIDUAL MONITORING IS NOT UTILIZED

Olivera Ciraj-Bjelac, Danijela Arandjic, Predrag Bozovic, Sandra Ceklic, Jelena Stankovic, Djordje Lazarevic

Pages: 57-61

DOI: 10.21175/RadJ.2016.01.11

Received: 15 MAR 2015, Received revised: 08 APR 2015, Accepted: 12 APR 2015, Published Online: 28 APR 2016

Fluoroscopy procedures may lead to increased radiation exposure of radiologists and other staff members. The objective of the study is to assess whole body radiation doses and doses to the eye in fluoroscopy procedures, based on measurements that allow for estimates of occupational doses when personal dosimeters have not been used. Four geometrical configurations were considered: overcouch x-ray tube with and without table mounted lead rubber curtains in place, undercouch x-ray tube with horizontal x-ray beam and undercouch x-ray tube with vertical x-ray beam. The doses were estimated using distribution of the scattered radiation and typical workload, as well as the pattern of used of protective tools. Estimated effective dose was in the range from few to 60 µSv per procedure for radiologist, and from few to 20 µSv per procedure for radiographer, depending on the geometrical configuration and level of personal protection. Corresponding unprotected eye doses were estimated to be in the range 0.03 – 2.8 mSv per procedure for radiologist and 0.02-0.78 mSv for radiographer. The presented results allowed for realistic estimations of the occupational whole body dose and dose to the eyes from the workload of the staff members and from the level of use of radiation protection tools when personal dosimeters have not been regularly used.
  1. “Avoidance of Radiation Injuries from Medical Interventional Procedures, ICRP Publication 85,” J. Valentin, Ed., Ann. ICRP 30, no. 2, June 2000.
  2. K. Faulkner and B. M. Moores, “An Assessment of the Radiation Dose Received by Staff Using Fluoroscopic Equipment,” Br. J. Radiol., vol. 55, pp. 272-276, May 1982.
    DOI: 10.1259/0007-1285-55-652-272
  3. E. Vano, N.J. Kleiman, A. Duran, M. Romano-Miller and M.M. Rehani, “Radiation-Associated Lens Opacities in Catheterization Personnel: Results of a Survey and Direct Assessments,” J. Vasc. Interv. Radiol., vol. 24, no. 2, pp. 197-204, Feb. 2013.
    DOI: 10.1016/j.jvir.2012.10.016
  4. E. Vano, N.J. Kleiman, A. Duran, M.M. Rehani, D. Echeverri and M. Cabrera, “Radiation Cataract Risk in Interventional Cardiology Personnel,” Radiat. Res., vol. 174, no. 4, pp. 490-495, Oct. 2010.
    DOI: 10.1667/RR2207.1
  5. M.M. Rehani et al.,. “Radiological Protection in Fluoroscopically Guided Procedures Performed Outside the Imaging Department. ICRP Publication 117,” Ann. ICRP, vol. 40, no. 6, pp. 1-102, Dec. 2010.
    DOI: 10.1016/j.icrp.2012.03.001
  6. International Commission on Radiological Protection. (April 21, 2011). ICRP ref 4825-3093-1464 Statement on Tissue Reactions. Retrieved from: http://www.icrp.org/docs/ICRP%20Statement%20on%20Tissue%20Reactions.pdf
  7. O. Ciraj-Bjelac, M. Rehani, A. Minamoto, K.H. Sim, H.B. Liew and E. Vano, “Radiation-Induced Eye Lens Changes and Risk for Cataract in Interventional Cardiology,” Cardiology, vol. 123, no. 3, pp. 168-171, Oct. 2012.
    DOI: 10.1159/000342458
  8. Y. Kong, L. Struelens, F. Vanhavere, C.S. Vargas, W. Schoonjans, W.H. Zhuo, “Influence of Standing Positions and Beam Projections on Effective Dose and Eye Lens Dose of Anaesthetists in Interventional Procedures,” Radiat. Prot. Dosim, vol. 163, no. 2, pp. 181-187, Feb. 2015.
    DOI: 10.1093/rpd/ncu148
  9. E. Vano, L. Gonzalez, J.M. Fernandez, Z.J. Haskal. “Eye Lens Exposure to Radiation in Interventional Suites: Caution is Warranted,” Radiol., vol. 248, no. 3, pp. 945-953, Sep. 2008.
    DOI: 10.1148/radiol.2482071800
  10. E. Vano, L. Gonzalez, E. Guibelalde, J.M. Fernandez and J.I. Ten, “Radiation Exposure to Medical Staff in Interventional and Cardiac Radiology,” Br. J. Radiol., vol. 71, pp. 974-960, Sep. 1998.
    DOI: 10.1259/bjr.71 .849.10195011
  11. E. Vano, J.M. Fernandez, R. Sanchez, L.T. Dauer, “Realistic Approach to Estimate Lens Doses and Cataract Radiation Risk in Cardiology When Personal Dosimeters Have not Been Regularly Used,” Health Phys., vol. 105, no. 4, pp. 330-339, Oct. 2013.
    DOI: 10.1097/HP.0b013e318299b5d9
  12. C.J. Martin, “A Review of Radiology Staff Doses and Dose Monitoring Requirements,” Rad. Prot. Dos., vol. 136, no. 3, pp. 140-157, Sep. 2009.
    DOI: 10.1093/rpd/ncp168
  13. O. Ciraj-Bjelac, M.M. Rehani, “Eye Dosimetry in Interventional Radiology and Cardiology: Current Challenges and Practical Considerations,” Rad. Prot. Dosim., vol. 162, no. 3, Nov. 2013.
    DOI: 10.1093/rpd/nct291
  14. Medical Electrical Equipment. Part 1: General Requirements for Safety. 3. Collateral Standard: General Requirements for Radiation Protection in Diagnostic X-Ray Equipment, IEC 601-1-3, 1994.
  15. International Commission on Radiological Protection. (March, 2007). ICRP Publication 103: The 2007 recommendations of the International Commission on Radiological Protection.
  16. Handbook of Anatomical Models for Radiation Dosimetry (Series in Medical Physics and Biomedical Engineering), 1st ed., X.G. Xu and K.F. Eckerman, Eds., CRC, Taylor and Francis, New York (NY), USA, 2009.
Radiation Protection

RADIATION LEVELS AT CARRYING OUT THE REFURBISHMENT OF THE BULGARIAN RESEARCH REACTOR IRT 2000

I. S. Dimitrov, Tz. Nonova, Al. Mladenov, K. Krezhov

Pages: 62-68

DOI: 10.21175/RadJ.2016.01.12

Received: 01 APR 2015, Received revised: 07 MAY 2015, Accepted: 08 MAY 2015, Published Online: 28 APR 2016

The paper presents a summary of the main steps in carrying out the refurbishment of the research reactor IRT in Sofia. It was a 2 MW pool type light water cooled and moderated reactor which after the final shutdown was defueled and brought to a state of safe enclosure. According to a decision of the Bulgarian Government it undergoes a reconstruction into a low-power reactor. In this regard during the period 2008 - 2014 within the IRT-Sofia took place a number of activities with potential for radiation hazard such as shipping of the spent nuclear fuel, dismantling of the reactor internals and replacement of aged reactor equipment, categorization, sorting and packaging for temporary storage of dismantled equipment and the radioactive waste generated during the dismantling activities. The report gives information on the organization and management of the activities and outlines some key technical aspects of the dismantling and removal of the contaminated/activated components. Also, the experience gained during this project is highlighted, particularly with a view to methods for the separation of radioactive waste from material to be cleared. The radiation measurements and site monitoring prior, for the period of all the activities and at present supplied comprehensive evidence that the work has been accomplished safely for the personnel and without radiation consequences for environment.
  1. E.P. Ryazantsev, “50th Anniversary of the IRT Reactor (History of Creation and Development),” Atom. Ener., vol. 104, no. 6, pp.470-482, June 2008.
    DOI: 10.1007/s10512-008-9057-2
  2. K. Krezhov, “The Research Reactor IRT-Sofia: 50 Years after First Criticality”, in Proc. Int. Conf. on Res. Reactors: Safe Manag. Eff. Utilization, vol. IAEA-CN-188, Rabat, Morocco, Nov. 14-18, 2011.
  3. “Detailed Plan for the Partial Dismantling of the IRT-2000 before its Reconstruction into a Low Power Reactor”, AtomEnergoproject, Moscow, Russia, Feb. 2009.
  4. D. Stankov, Al. Mladenov, K. Marinov, Tz. Nonova and K. Krezhov, “Individual Dosimetric Control and Monitoring of the Working Environment at the Nuclear Site IRT – Sofia”, In Proc. EMPEC 2012, Sofia, Bulgaria, Oct. 18-20, 2012, pp. 354-359.
  5. A. Mladenov, D. Stankov, Tz. Nonova, K. Krezhov. “Radiation Protection, Radioactive Waste Management and Site Monitoring at the Nuclear Scientific Experimental and Educational Centre IRT-Sofia at INRNE – BAS”, Rad. Prot. Dosim., vol. 162, no. 1-2, pp. 176-181, 2014.
    DOI: 10.1093/rpd/ncu254
  6. Bulgarian Nuclear Regulatory Agency. (2004). Regulation on the terms and procedure for delivery of radioactive waste to the Radioactive Waste State-Owned Company.
  7. Bulgarian Nuclear Regulatory Agency. (2012). Regulation on Basic Norms of Radiation Protection (BNRP).
  8. Bulgarian Nuclear Regulatory Agency. (2004). Regulation on ensuring the safety of research nuclear installations.
  9. Bulgarian Nuclear Regulatory Agency. (2004) Regulation on safety during decommissioning of nuclear facilities.
  10. Bulgarian Nuclear Regulatory Agency. (2012). Regulation for radiation protection during activities with sources of ionizing radiation.
  11. Nuclear Safety Standards Commission and IAEA. (2012) Monitoring the Discharge of Radioactive Substances from Research Reactors.
  12. Nuclear Safety Standards Commission and IAEA. (2008), Radiation Protection and Radioactive Waste Management in the Design and Operation of Research Reactors.
  13. IAEA. (1998). IAEA TECDOC No. 1012 Durability of Spent Nuclear Fuels and Facility Components in Wet Storage.
  14. Bulgarian Nuclear Regulatory Agency. (2014). Regulation on the Conditions and Procedure of Transport of Radioactive Material.
  15. Bulgarian Nuclear Regulatory Agency. (2012). Regulation on the Procedure for Issuing Licenses and Permits for Safe Use of Nuclear Energy.
  16. Tz. Nonova, D. Stankov, Al. Mladenov, K. Krezhov. “Radiological characterization activities during the partial dismantling of the IRT - Sofia research reactor facilities”, Roman. J. Phys., vol. 59 (9-10), pp. 976 – 988, 2014.
  17. Al. Mladenov, Tz. Nonova, D. Stankov, K. Krezhov, “Possibilities of Automatic Radiation Monitoring System in Nuclear Scientific Experimental and Educational Centre”, in Proc. 2nd Nat. Cong. of Phys. Sci. and 41st Nat. Conf. Phys. Educ., Sofia, Bulgaria, Sep. 18-20, 2013.
Radiation Protection

RADIATION PROTECTION ASPECTS RELEVANT TO RADIOLOGICAL TERRORISM

Jana Hudzietzová, Jozef Sabol, Bedřich Šesták

Pages: 69-75

DOI: 10.21175/RadJ.2016.01.13

Received: 15 MAR 2015, Received revised: 11 MAY 2015, Accepted: 13 MAY 2015, Published Online: 28 APR 2016

The paper summarizes some basic issues related to the protection of people against the danger resulting from a radiological weapon or the so-called dirty bomb which can potentially be used in terrorist or other malevolent attacks. The properties of radioactive material utilized for this purpose and the quantification of the exposure of affected persons, the prevention measures against and consequences of radiological acts as well as appropriate arrangements aimed at minimizing their impacts are described. In addition, an overview of global initiatives addressing the fight against terrorism in general, including CBRN terrorism, is also presented.
  1. International Commission on Radiological Protection. (2007). ICRP Publication 103, The 2007 Recommenda-tions of the International Commission on Radiological Protection.
  2. P.K. Karam, “Radiological terrorism”, Hum. Ecol. Risk Assess., vol. 11, iss. 3, pp. 501-523, Jan., 2005.
    DOI: 10.1080/10807030590949618
  3. J. Cirincionne, J.B. Wolfstahl, M. Rajkumar, Deadly Arsenals – Nuclear, Biological, and Chemical Threats, Washington DC, USA: Carnegie Endowment for International Peace, 2005.
  4. IAEA Safety Standards Series no. RS-G-1.9: Categorization of Radioactive Sources. IAEA, Vienna, Austria, 2005.
  5. D. Delacroix, J.P. Guerre, P. Leblanc and C. Hickman, “Radionuclide and Radiation Protection Data Handbook 1998,” 1st ed., Rad. Prot. Dosim., vol. 76, no. 1-2, pp. 1-126, 1998.
  6. K. Eckerman, J. Harrison, H-G. Menzel and C.H. Clement (auth. on behalf of ICRP), “ICRP Publ. 119: Compendium of Dose Coefficients Based on ICRP Publication 60,” Ann. ICRP, vol. 41, 2012.
    DOI: 10.1016/j.icrp.2012.06.038
  7. HotSpot, Health Physics Codes for the PC, National Atmospheric Release Advisory Center, Lawrence Livermore National Laboratory, CA, USA. Retrieved from: https://narac.llnl.gov/HotSpot/HotSpot.html.
  8. EU CBRN Action Plan. Retrieved from: http://www.ebsaweb.eu/ebsa_media/ANNEXE1_COM_2009_ 273-p-1304.pdf
  9. Ј. Sabol et al., “The Role of International Organizations in Combatting Radiological Terrorism”, Secur. Rev., Feb. 21, 2011. Retrieved from: http://www.securityrevue.com/ article/2011/02/the-role-of-international-organizations-in-combatting-radiological-terrorism/
  10. “Can the EU’s Centres of Excellence Initiative Contribute Effectively to Mitigating Chemical, Biological, Radiological and Nuclear Risks from Outside the EU?” ECA, Luxembourg, Spec. Rep. 17, 2014.
    DOI: 10.2865/31640
Radon and Thoron

RADON LEVELS IN PORTUGUESE THERMAL SPAS

A.S. Silva, M.L. Dinis, A.J.S.C. Pereira, A. Fiúza

Pages: 76-80

DOI: 10.21175/RadJ.2016.01.14

Received: 23 MAR 2015, Received revised: 29 APR 2015, Accepted: 04 MAY 2015, Published Online: 28 APR 2016

adon concentration measurements were performed in indoor air and in natural mineral waters in seventeen Portuguese thermal spas used for therapy, drinking and irrigation purposes. The gamma doses rates were also assessed in different workplaces of the considered thermal spas. The radon concentration was measured in water samples taken from different sampling points: boreholes, springs, inhalator chambers (ORL’s) and swimming pools, and in the indoor air of different treatment rooms: ORL’s, swimming pools, vapours areas and Vichy shower. Radon concentration in water ranged from 26 to 6949 Bq/L and in the indoor air ranged from 73 Bq/m3 to 3479 Bq/m3. The indoor gamma dose rates ranged from 0,148 µSv/h to 0,644 µSv/h and the annual dose rate was estimated ranging from 0,30 to 1,29 mSv/y, for 2000 working hours per year, which is far below the effective dose limit for workers (20 mSv/y). Nevertheless, the great contribution for the annual effective dose will result from radon inhalation which is not included in this estimation. The remedial action level for drinking water of 1000 Bq/L (2001/928/ EURATOM) was exceeded in 23% of the selected thermal spas and about 80% of the total measurements of the indoor radon concentration exceeded the previous reference level of 200 Bq/m3 for new buildings and about 63% exceeded the new reference level of 300 Bq/m3 as established in the Directive 2013/59/EURATOM for indoor radon concentration in workplaces. Therefore, as the recommended limits for radon concentration in water and in indoor air were exceeded, appropriate actions should be taken in order to reduce the hazard to health from radon indoors and the potential resulting occupational exposure.
  1. S. Alberigi, B.R. Pecequilo, H.A. Lobo and M.P. Campos, “Assessment of Effective Doses from Radon Levels for Tour Guides at Several Galleries of Santana Cave, Southern Brazil, with CR-39 Detectors: Preliminary Results,” Rad. Prot. Dos., vol. 145, no. 2-3, pp. 252–255, Mar. 2011.
    DOI: 10.1093/rpd/ncr054
  2. Y. Yarar, T. Gunaydi, N. Celebi, “Determination of Radon Concentrations of the Dikili Geothermal Area in Western Turkey,” Rad. Prot. Dos., vol. 118, no. 1, pp.78–81, Feb. 2006.
    DOI: 10.1093/rpd/nci321
  3. M. Erdogan, F. Ozdemir and N. Eren, “Measurements of Radon Concentration Levels in Thermal Waters in the Region of Konya, Turkey,” Isot. Environ. Health Stud., vol. 49, no. 4, pp. 567–574, Aug. 2013.
    DOI: 10.1080/10256016.2013.815182
  4. T.O. Santos, Z. Rocha, P. Cruz, V.A. Gouvea, J.B. Siqueira and A.H. Oliveira, “Radon Dose Assessment in Underground Mines,” Rad. Prot. Dos., vol. 160, no. 1-3, pp. 120-123, Apr. 2014.
    DOI: 10.1093/rpd/ncu066
  5. D. Nikolopoulos, E. Vogiannis, E. Petraki, A. Zisos and A. Louizi, “Investigation of the Exposure to Radon and Progeny in the Thermal Spas of Loutraki (Attica-Greece): Results from Measurements and Modelling,” Sci. of the Total Environ., vol.408, iss.3, pp. 495–504, Jan. 2010.
    DOI: 10.1016/j.scitotenv.2009.09.057
  6. T. Vaupotic, T. Streil, S. Tokonami and Z.S. Zunic, “Diurnal Variations of Radon and Thoron Activity Concentrations and Effective Doses in Dwellings in Niska Banja, Serbia,” Rad. Prot. Dos., vol. 157, no. 3, pp. 375-382, 2013.
    DOI: 10.1093/rpd/nct145
  7. A.S. Silva, M. L. Dinis and A. Fiuza, “Research on Occupational Exposure to Radon in Portuguese Thermal Spas,” in Occupational Safety and Hygiene II, P.M. Arezes et al., Eds., London, England: Taylor & Francis, 2014, ch. 57, pp. 323 -328.
    DOI: 10.1201/b16490-58
  8. J. Nikolov et al., “Radon in Thermal Waters in South-East Part of Serbia,” Radiation Protection Dos., vol. 160, no. 1-3, pp. 239-243, 2014.
    DOI: 10.1093/rpd/ncu094
  9. A. Koray, G. Akkaya, A. Kahraman and G. Kaynak, “Measurements of Radon Concentrations in Waters and Soil Gas of Zonguldak,” Rad. Prot. Dosim., vol. 162, no. 3, pp. 375-387, Nov. 2013.
    DOI: 10.1093/rpd/nct308
  10. M.A. Ziane, Z. Lounis-Mokrani and M. Allab, “Exposure to Indoor Radon and Natural Gamma Radiation in Some Workplaces at Algiers, Algeria,” Rad. Prot. Dosim., vol. 160, no. 1-3, pp. 128-133, July 2014.
    DOI: 10.1093/rpd/ ncu058
  11. N. Kavasi et al., “Effect of Radon Measurement Methods on Dose Estimation,” Rad. Prot. Dosim., vol. 145, no. 2-3, pp. 224-232, 2011.
    DOI: 10.1093/rpd/ncr044
  12. F. Oner, I. Yigitoglu and H.A. Yalim, “Measurements of Radon Concentration in Spa Waters in Amasya, Turkey,” Rad. Prot. Dosim., vol. 157, no. 2, pp. 221-224, May 2013.
    DOI: 10.1093/rpd/nct130
  13. K. Jile, M. Slezákova and J. Thomas, “Diurnal and Seasonal Variability of Outdoor Radon Concentration in the Area of the NRPI Prague,” Rad. Prot. Dosim., vol. 160, no. 1-3, pp. 57-61, 2014.
    DOI: 10.1093/rpd/ncu091
  14. M. Moldovan et al., “Radon and Radium Concentration in Water from North-West of Romania and the Estimates Doses,” Rad. Prot. Dosim., vol. 162, no. 1-2, pp. 96-100, 2014.
    DOI: 10.1093/rpd/ncu230
  15. G. Trabidou and H. Florou, “Estimation of doses rates to humans exposed to elevated natural radioactivity through different Pathways in the Island of Ikaria, Greece,” Rad. Prot. Dosim., vol. 142, no. 2-4, pp. 378-384, 2010.
    DOI: 10.1093/rpd/ncq269
  16. M. Pugliese, M. Quarto and V. Roca, “Radon Concentra-tions in Air and Water in the Thermal Spas of Ischia Island,” Indoor and Built Environ., vol. 23, no. 6, pp. 823-827, 2013.
    DOI: 10.1177/1420326X13480053
  17. S. Labidi, F. Essafi and H. Mahjoubi, “Estimation of the Radiological Risk Related to the Presence of Radon 222 in a Hydrotherapy Centre in Tunisia,” J. Radiol. Prot., vol. 26, no. 3, pp. 309-316, 2006.
    DOI: 10.1088/0952-4746/26/3/005
  18. A.S. Silva and M. L. Dinis, “The Presence of Radon in Thermal Spas and their Occupational Implications – a review,” in Occupational Safety and Hygiene III, P. Arezes et al., Eds., London, England: Taylor & Francis, 2015, ch. 13, pp. 59 – 65.
    DOI: 10.1201/b18042-14
  19. Standard Test Method for Radon in Drinking Water, ASTM D5072-09e1, 2009. Retrieved from: http://www.astm.org/DATABASE.CART/HISTORICAL/D5072-09E1.htm
  20. R. Rusconi et al., “The Monitoring of Tap Waters in Milan: Planning Methods and Results,” Rad. Prot. Dosim., vol. 111, no. 4, pp. 373-376, 2004.
    DOI: 10.1093/rpd/nch057
  21. C.V.M. Goncalves and A.J.S.C. Pereira, “Radionuclides in Groundwater of the Serra do Bucaco Region (Central Portugal),” in Proc. of the XXXV Congr. of the Int. Assoc. of Hydrogeol., Lisbon, Portugal, 2007, pp.
  22. A. Louro et al., “Human Exposure to Indoor Radon: a Survey in the Region of Guarda, Portugal,” Rad. Prot. Dosim., vol. 154, no. 2, pp. 237-244, Apr. 2013.
    DOI: 10.1093/rpd/ncs166
Radon and Thoron

ERROR ASSESSMENT ON THE PLANNING STAGE OF NATIONAL RADON CASE-CONTROL STUDY

A. Onishchenko, A. Varaksin, I. Yarmoshenko, M. Zhukovsky

Pages: 81-87

DOI: 10.21175/RadJ.2016.01.15

Received: 14 MAR 2015, Received revised: 07 APR 2015, Accepted: 10 APR 2015, Published Online: 28 APR 2016

The possible influence of errors of radon exposure assessment on the results of planned national case-control study has been analyzed. It is demonstrated that, in general, the errors are classical multiplicative errors. It is demonstrated that the classical multiplicative errors of radon concentration measurement are not constant in all radon concentration ranges. At low radon concentrations, the additional influence of Poisson error on the measurement result should be considered. The modeling of the influence of errors of radon exposure assessment on slope factor of the dependence of lung cancer incidence on radon concentration in dwellings was conducted. It was shown that the expected level of radon exposure errors can reduce the observed value of slope coefficient at least twice in comparison with the original value for error-free study. The correction of the results of linear assessment of exposure-effect slope coefficient under the influence of measurement errors was realized by regression calibration technique and SIMEX extrapolation method. Regression calibration method gives the best results in restoring the original unbiased value of exposure-effect slope coefficient. The SIMEX method also allows the obtainment of the good assessment of expected value of the slope of exposure-effect dependence, but it should be noted that this method may lead to the underestimation of the real value of slope coefficient. An additional and the most powerful source of error in the radon epidemiological studies is the influence of smoking and the correlation between smoking status and radon concentration in dwellings. The modeling results demonstrated that maximum attention should be paid to the stratification by smoking status and other possible factors simultaneously influencing radon concentration in dwellings and lung cancer incidence.
  1. S. Darby et al., “Residential Radon and Lung Cancer: Detailed Results of a Collaborative Analysis of Individual Data on 7148 Subjects with Lung Cancer and 14208 Subjects without Lung Cancer from 13 Epidemiologic Studies in Europe,” Scand. J. Work. Environ. Health, vol. 32, suppl. 1, pp. 1-83, 2006.
  2. S.X. Yao et al., “Exposure to Radon Progeny, Tobacco use and Lung Cancer in a Case–Control Study in Southern China,” Radiat. Res., vol. 138, no. 3, pp. 326–336, 1994.
    DOI: 10.1016/0169-5002(95)96279-5
  3. J. H. Lubin et al. “Risk of Lung Cancer and Residential Radon in China: Pooled Results of two Studies”, Int. J. Cancer, vol. 109, no. 1, pp. 132–137, Mar. 2004.
    DOI: 10.1002/ijc.11683
  4. D. Krewski et al., “Residential Radon and Risk of Lung Cancer: a Combined Analysis of 7 North American Case-Control Studies,” Epidemiology, vol. 16, no. 2, pp.137-145, Mar. 2005.
    DOI: 10.1097/01.ede.0000152522.80261.e3
  5. J.H. Lubin, J.D. Boice Jr. and J.M. Samet, “Errors in Exposure Assessment, Statistical Power and the Interpretation of Residential Radon Studies,” Radiat. Res., vol. 144, pp. 329–341, Dec. 1995.
    DOI: 10.2307/3578953
  6. Е.В. Ползик, В.Л. Лежнин и В.С. Казанцев, “К проблеме оценки влияния радона на развитие рака легких,” Радиационн. биол.Радиоэк., т. 44, № 2, c. 207-215, 2004. (E.V. Polzik, V.L. Lezhnin and V.S. Kazantsev, “Towards the Issue of Evaluating the Radon Effects on Lung Cancer,” Radiat. Biol. Radioecol., vol. 44, no. 2, pp. 207-215, 2004.)
  7. V.L. Lezhnin, E.V. Polzik, V.S. Kazantsev, M.V. Zhukovsky and O.A. Pakholkina, “A Multifactorial Assessment of Carcinogenic Risks of Radon for the Population Residing in a Russian Radon Hazard Zone,” Arch. Oncol., vol. 19, no. 1-2, pp. 3-8, 2011.
    DOI: 10.2298/AOO1102003L
  8. M. Zhukovsky, A. Varaksin and O. Pakholkina “Statistical Analysis of Observational Study of the Influence of Radon and Other Risk Factors on Lung Cancer Incidence,” Rad. Prot. Dosim., vol. 160, no. 1-3, pp. 108-111, 2014.
    DOI: 10.1093/rpd/ncu069
  9. Y. Yamada et al., “Radon–Thoron Discriminative Measurements in Gansu Province, China, and their Implication for Dose Estimates,” J. Toxicol. Environ. Health, Pt. A, vol. 69, no.7, pp. 723–734, 2006.
  10. T. Fearn, D.C. Hill and S.C. Darby, “Measurement Error in the Explanatory Variable of a Binary Regression: Regression Calibration and Integrated Conditional Likelihood in Studies of Residential Radon and Lung Cancer”, Dept. of Statist. Sci., Univ. College London, England, Research Rep. 280, Oct. 2007.
    DOI: 10.1002/sim.3163
  11. “European Detailed Mortality Database (DMDB),” World Health Organization, Regional Office for Europe. Retrieved from: http://data.euro.who.int/dmdb/; Retrieved on: 2014.
  12. R. Peto, A.D. Lopez, J. Boreham, M. Thun and C. Heath Jr., “Mortality from Tobacco in Developed Countries: Indirect Estimation from National Vital Statistics,” Lancet, vol. 339, pp. 1268-1278, May 1992.
    DOI: 10.1016/0140-6736(92)91600-D
  13. C.B. Howarth, “Results of the 2006 Health Protection Agency Intercomparison of Passive Radon Detectors,” Health Protection Agency, 1st ed., Chilton, UK, 2007[T1], HPA-RPD-053.
  14. C.B. Howarth, “Results of the 2007 Health Protection Agency Intercomparison of Passive Radon Detectors,” Health Protection Agency, Chilton, UK, Nov. 2009, HPA-RPD-060
  15. Z. Daraktchieva, C.B. Howarth and R. Algar “Results of the 2011 HPA Intercomparison of Passive Radon Detectors,” Health Protection Agency, Chilton, UK, May 2012, HPA-CRCE-033.
  16. B.S. Cohen, “Variation of Radon Levels in U.S. Homes Correlated with House Characteristics, Location, and Socioeconomic Factors,” Health Phys., vol. 60, no. 5, pp. 631-642, May 1991.
    DOI: 10.1097/00004032-199105000-00001
  17. Z.S. Zunic et al., “Radon Survey in the High Natural Radiation Region of Niska Banja, Serbia,” J. Environ. Radioact., vol. 92, no. 3, pp. 165 – 174, 2007.
    DOI: 10.1016/j.jenvrad.2006.11.002
  18. J.R. Cook and L.A. Stefanski, “Simulation-Extrapolation Simulation in Parametric Measurement Error Models,” J. Amer. Stat. Asso., vol. 89, no. 428, pp. 1314-1328, Dec. 1994.
    DOI: 10.2307/2290994